Skip to main content
. 2018 Oct 31;5:1491–1497. doi: 10.1016/j.mex.2018.10.022
Subject area Environmental Science
More specific subject area Soil microbial ecology
Method name High-throughput PLFA analysis
Name and reference of original method J.S. Buyer, M. Sasser, High-throughput phospholipid fatty acid analysis of soils, Appl. Soil Ecol. 61 (2012) 127-130.
Resource availability
  • -

    Freeze-drier and pump (e.g. Alpha 2-4 LD, Christ, Germany; Vacuubrand 2.5, Germany).

  • -

    Internal standard (e.g. 19:0 phosphatidylcholine, Avanti Polar Lipids, Alabaster, AL, US).

  • -

    External standard (e.g. Bacterial Acid Methyl Ester, Supelco, Sigma Aldrich, US).

  • -

    Solid phase extraction columns (e.g. HyperSep™ SI columns, 50 mg/1 ml, Thermo Scientific, US).

  • -

    Centrifugal evaporator with vacuum pump, cold trap and rotor (e.g. miVac Duo Concentrator; miVac Duo Pump; miVac Speed Trap; rotor DRC-13100-032, GeneVac, UK). Nitrogen evaporation could be used instead of this equipment, if required.

  • -

    GCMS, column and processing software (e.g. Trace GC Ultra and DSQ II, Thermo Scientific, US; ZB-FFAP, Phenomenex®,Macclesfield, UK; Xcalibur®, Thermo Fisher Scientific, US).