Skip to main content
. 2018 Aug 9;12(6):722–727. doi: 10.5009/gnl17468

Table 2.

Overall Outcomes of Endoscopic Bilateral Stent-in-Stent Placement Using Large Cell-Type Stents for Inoperable Malignant Hilar Biliary Obstruction

Outcomes Data
Technical success 38/43 (88.4)
Technical failure 5/43 (11.6)
 Bismuth type II/IIIa/IIIb/IV 0/2/1/2
 Failure in guidewire reinsertion via first stent mesh 1
 Second stent delivery passage failure via first stent mesh 4
Functional success 38/43 (88.4)
Stent occlusion 24/38 (63.2)
 Tumor ingrowth 17
 Tumor ingrowth and overgrowth 4
 Biliary sludge 3
Overall stent patency 198 (68–328)
 Patency rate at 3/6/12 mo, % 82.9/63.1/32.1
Overall patient survival, day 300 (144–455)
Endoscopic/percutaneous re-intervention, n (%) 14 (58.3)/10 (41.7)

Data are presented as number/number (%) or median (interquartile range).