Figure 1.

Figure 1

A) A schematic diagram including T2, fat suppression, and α/2 preparation RF pulses prior to b-SSFP readout. Two rays per heart beat are acquired along the head-to-foot and oblique anterior-to-posterior directions to track motion. B) The inner 10% of central partitions (labeled as region II) were sampled twice as densely as compared to the outer 90% partitions (labeled as region I). C) Outer-in and center-out kz orderings were compared to determine which ordering produces better fat suppression. The center-out kz ordering was found to produce superior fat suppression (green arrow) than the outer-in kz ordering as shown.