Skip to main content
. Author manuscript; available in PMC: 2019 Nov 1.
Published in final edited form as: J Electrocardiol. 2018 Aug 1;51(6 Suppl):S78–S82. doi: 10.1016/j.jelectrocard.2018.07.026

Table 2.

Learning curve and quantitative evaluation of model performance at group level, including AUC, sensitivity, specificity and F1 score.

# Training
Recordings
AUC
(median: range)
Sensitivity
(median: range)
Specificity
(median: range)
F1 Score
(median: range)
5 86.71:
64.72–99.20%
82.08:
56.00–100%
77.88:
36.81–96.41%
84.27:
52.85–97.82%
10 84.11:
57.63–98.47%
80.92:
41.29–99.42%
73.01:
47.74–97.58%
83.32:
60.53–98.45%
15 86.69:
63.12–99.26%
80.20:
56.74–99.29%
79.94:
61.45–96.39%
84.92:
73.36–97.27%
20 87.88:
65.14–99.30%
80.56:
47.25–100%
80.22:
57.41–95.96%
85.82:
71.19–96.97%
25 87.74:
63.73–99.27%
81.92:
51.91–100%
81.44:
61.74–95.97%
87.31:
73.93–96.97%
30 87.87:
63.07–99.28%
82.64:
50.08–100%
80.34:
59.49–96.08%
87.38:
72.44–97.69%