Skip to main content
. 2018 Nov 14;18(11):3926. doi: 10.3390/s18113926

Table 1.

Linearity range and LOD of CFP10 antigen using different immunoassay method.

No. Detection Method Linear Range LOD References
1. Enzyme-linked immunosorbent assay (ELISA) Not reported 0.35 IU/mL [37]
2. Plasmonic ELISA 0–0.1 µg/mL 0.01 µg/mL [38]
3. Magnetophoretic immunoassay 1 pM–1 mM 0.3 pM [39]
4. Surface plasmon resonance (SPR) 0.1 to 1 μg/mL 100 ng/mL [40]
5. Electrochemical 20–100 ng/mL 15 ng/mL This work