Table 3.
Study | Environment | Studied LoRaWAN Performance Indicators | Comments | |||
---|---|---|---|---|---|---|
Path Loss | PLR | Throughput | Delay | |||
[32] | Outdoor | Yes | Yes | No | No | @2 km distance using SF12 RSSI > −90 dBm; PLR = 12% |
[33] | Outdoor | Yes | No | No | No | @2 km distance coverage only using SF12 |
[34] | Outdoor | Yes | Yes | Yes | No | @2 km distance using SF12 PLR = 3% |
[18] | Outdoor-Indoor | Yes | Yes | No | No | @2 km distance RSSI > −100 dBm AXK rcp = 42% |
[35] | Indoor | Yes | Yes | Yes | Yes | @60 m distance with SF12 RSSI > −100 dBm PLR = 2% |
[36] | Indoor | Yes | Yes | No | No | @60 m distance with SF12 RSSI > −100 dBm PLR = 2% |
[37] | Indoor | Yes | No | No | No | @~32 m distance RSSI > −75 dBm |
[39] | Industrial | Yes | Yes | No | No | @~190 m distance RSSI > −100 dBm PLR < 1/% |
[24] | City Outdoor | Yes | No | No | No |