Skip to main content
. 2011 Sep 5;16(9):7522–7550. doi: 10.3390/molecules16097522

Table 12.

Key parameters of batch vs. microreactors used.

batch μ-Reactor μ-Chip μ-Capillary tower
Pyrex test tube 9 mm (ID) / 10 mm (OD) 15 mL (Vsolution) mikroglas chemtech dwell device (Foturan™) 2,000 μm × 500 μm × 1.15 m (W × D × L) 1.68 mL (Vchannel) Micronit Microfluidics (Borofloat®) 150 μm × 150 μm × 757 mm (W × D × L) 13 μL (Vchannel) PTFE capillary (wrapped around a Pyrex cylinder) 558 μm × 460 cm (ID × L) 2 capillaries 2 × 1.12 mL (Vcapillary)
Rayonet chamber reactor (RPR-200) equipped with 16 × 8 W UVA lamps Luzchem UV panel equipped with 5 × 8 W UVA lamps 6 × 75 mW 365 nm UV-LED array 1 × 8 W UVA lamp (inside the Pyrex cylinder)