Table 3.
Preferred Practice Pattern Element | Percent Compliance in Patients with One Visit (n=118) | Percent Compliance in Patients with > 1 Visit (n=242) | P-values * |
---|---|---|---|
Ocular history | 99% | 100% | P=0.3278 |
Systemic history | 98% | 100% | P=0.0346 |
Family history | 97% | 99% | P=0.2245 |
Review of systems | 98% | 100% | P=0.0346 |
Medications | 98% | 100% | P=0.2488 |
Visual acuity measurement | 99% | 100% | P=0.3278 |
Pupil examination | 100% | 100% | |
Slit lamp examination of anterior segment | 100% | 100% | |
Intraocular pressure measurement | 100% | 100% | |
Gonioscopy | 22% | 60% | P<0.0001 |
Optic nerve head and retinal nerve fiber layer examination with imaging | 99% | 100% | P=0.5437 |
Dilated fundus examination | 87% | 93% | P=0.0795 |
Central corneal thickness | 77% | 94% | P<0.0001 |
Visual field evaluation | 41% | 98% | P<0.0001 |
Target intraocular pressure selected | 2% | 22% | P<0.0001 |
Bivariate analysis performed using Fisher’s exact testing