Echocardiographic data, hemodynamic parameters and laboratory data before and after treatment of allograft rejection in case 2.

10 June 2010 1 October 2010 15 October 2010
ISHLT rejection grade 0 3R 1R
Echocardiographic data
 LVDd (mm) 43 44 45
 LVDs (mm) 22 25 25
 Ejection fraction (%) 81 75 77
 E wave (cm/s) 83.3 102 78.3
 A wave (cm/s) 21.7 38.9 26.2
 Ea wave (cm/s) 16.8 4.0
 Deceleration time (ms) 114 136 180
 E/A ratio 3.04 2.62 2.99
 E/Ea ratio 4.96 25.5
 eRVsP (mmHg) 28 31 32
Hemodynamic parameters
 RA a/v/mean (mmHg) 3/3/2 5/4/3 5/5/3
 RV systolic/end-diastolic (mmHg) 17/3 27/5 21/3
 PCW a/v/mean (mmHg) 6/7/5 11/12/9 12/10/7
 Cardiac output (L/min) 4.44 4.51 3.90
 Cardiac index (L/min/m2) 2.34 2.37 2.05
Laboratory data
 BNP (pg/mL) 28.1 187.3 96.6
 SaO2 (%) 97 96 96
 CTR of chest X-ray 49.2 52.8 51.0

LVDd/Ds, left ventricular end-diastolic/-systolic diameter; E wave, early diastolic mitral inflow wave; A wave, late diastolic mitral inflow wave; Ea wave, early diastolic mitral annular motion velocity; eRVsP, estimated right ventricular systolic pressure; RA, right atrium; RV, right ventricle; PA, pulmonary artery; PCW, pulmonary capillary wedge; BNP, B-type natriuretic peptide; CTR, cardiothracic ratio; SaO2, arterial oxygen saturation.