Table 1.
Purpose of simulation | Parameter space | Results |
---|---|---|
Dependence on varying alpha | α: [0 – 10] | Linear correlation with r squared= 0.99 |
Dependence on varying initial displacement | Δx0: [0 – 0.95] mm | Linear correlation with r squared = 0.99 (indicating constant amplification factor) |
Dependence on varying harmonics | n: [0 – 10] | Different harmonics were amplified equally |
Dependence on varying disk radius | r: [1.875 – 30] mm | Different phantom size were amplified equally |
Dependence on varying bar width | d: [3.75 – 60] mm | Different phantom size were amplified equally |
Dependence on varying phantom intensity over time | n: [0 – 10] | Varying phantom intensity did not effect the amplification |
Dependence on varying Rician noise | Rician noise parameter s:[0 – 0.01] mm | Different noise parameter were amplified equally |
Investigate coupling between motion and partial volume effect (PVE) | n: [0 – 4] Δl0: [0 – 0.2] |
Amplification parameter is independent of partial volume effect |