Table 2.

Troubleshooting for the pipette tip assay (s-ARU method)

Problems Solutions
Growth in the cell-free gap - The pipette tip is not properly fixed in the center of the well or
- Pipette tip is tilted or
- Pipette tip is short
The cell-free area is not spherical/circular - The cover plate is not fixed properly with paper tape or
- The plate was tempered or
- The medium and cells have entered under the pipette tip
Contamination - The pipette tips are not sterile/non-autoclaved or
- The pipette tips were not processed within the hood or
- The glue/fixative/adhesive used might have contaminated the medium due to over spilling or shaking
The cover plate does not fix the plate properly - The pipette tips are not homogeneously shortened or
- The pipette tip is not properly fixed in the center of the well
Results variation - The variation in results in mostly due to the density of the cells or
- Floating cells occupying the NO growth zone