Skip to main content
. Author manuscript; available in PMC: 2019 Nov 1.
Published in final edited form as: Chem Phys Lipids. 2018 Sep 7;216:162–170. doi: 10.1016/j.chemphyslip.2018.09.004

Table 1.

Calibration curve range, FA retention time, selected MS ion fragment, limit of detection (LOD) in femtograms (fg) on-column (OC), and lower limit of quantitation (LLOQ) in picograms (pg) for each of the quantified FAs. Trans- FAs found in plasma were assumed to have the same instrumental response as their commercially available cis- counterparts.

Fatty Acid Calibration Curve Range in pg on column; (in ng/mL) Retention Time (min) SRM Mass Transition LOD in fg OC; LLOQ in pg OC; (in ng/mL)
0–469; 4.3;
5,6-DHET (0–20) 5.8 505→239 25 (0.185)
0–469; 4.3;
8,9-DHET (0–20) 4.8 505→239 100 (0.185)
0–469; 4.3;
11,12-DHET (0–20) 4.0 505→239 100 (0.185)
0–469; 4.3;
14,15-DHET (0–20) 3.4 505→239 50 (0.185)
0–2340 26;
5-HETE (0–100) 9.8 487→283 50 (1.11)
0–2340; 26;
9-HETE (0–100) 8.7 487→307 50 (1.11)
0–2340; 26;
11-HETE (0–100) 7.6 487→335 50 (1.11)
0–2340; 26;
12-HETE (0–100) 7.9 487→347 50 (1.11)
0–2340; 26;
15-HETE (0–100) 6.9 487→183 10 (1.11)
0–350;s 1.7;
19-HETE (0–15) 4.8 487→183 50 (0.074)
0–350; 1.7;
20-HETE (0–15) 5.2 487→183 50 (0.074)
0–700; 4.0;
5,6-EET (0–30) 11.6 487→283 25 (0.185)
0–700; 4.0;
8,9-EET (0–30) 10.8 487→307 25 (0.185)
0–700; 4.0;
11,12-EET (0–30) 10.3 487→333 25 (0.185)
0–700; 4.0;
14, 15-EET (0–30) 9.0 487→333 75 (0.185)