Table 1.
Motor nerve conduction velocities and compound muscle action potential amplitudes for proximal and distal stimulations when recorded for radial (n = 5), ulnar (n = 6), tibial (n = 5), and peroneal (n = 8) nerves, in comparison with published values17
| Range | Mean | Reference | |||
|---|---|---|---|---|---|
| MNCV (m/s) | Radial | 16.9‐37 | 24 | 72.1 ± 1.9 | |
| Ulnar | 17‐37.5 | 25.1 | 58.9 ± 1 | ||
| Tibial | 20.5‐54.5 | 38 | 68.2 ± 1.4 | ||
| Peroneal | 14‐52.3 | 19.5 | 79.8 ±1.8 | ||
| Amp (mV) | Radial | Proximal | 3‐11.9 | 4.5 | 23.4 ± 1.5 | 
| Distal | 1.1‐13.1 | 6 | 21.6 ± 1.6 | ||
| Ulnar | Proximal | 0.4‐13.3 | 2.1 | 22.9 ± 1.6 | |
| Distal | 0.9‐16.1 | 1.7 | 25.8 ± 1.8 | ||
| Tibial | Proximal | 0.1‐21.8 | 14.1 | 20.1 ± 1.6 | |
| Distal | 0.2‐16.9 | 8.3 | 23.3 ± 2.3 | ||
| Peroneal | Proximal | 1‐26.6 | 7.9 | 19.8 ± 1.4 | |
| Distal | 2‐15.4 | 3.35 | 19.5 ± 1.5 | 
Amp, amplitude; MNCV, motor nerve conduction velocity.