Intra- and interassay precision and accuracy for determining pinosylvin in rat plasma, urine, feces, and various tissue homogenates (n=3 days, 5 replicates per day).

Bio-sample Nominal concentration (ng/mL) Inter-day (n=5) Intra-day (n=15)
Precision RSD (%) Accuracy R.E (%) Precision R.S.D (%) Accuracy R.E (%)
Plasma 5.4 2.7 7.5 3.7 9.4
135 10 -6.1 10.1 -7.4
540 4.8 0.2 9.4 6.5
Urine 1350 0.7 9.5 1.7 9.9
5400 8.6 -7.4 8 -7.8
54000 6.4 -6.3 4.5 -2.9
Feces 270 8.6 -5.4 9.8 2.4
2700 8.3 -3.6 9.6 -1.1
5400 9.3 -3.5 9.5 -5.9
Heart 540 9.1 -4.7 9.8 6.4
5400 4.4 2.1 7.3 4.1
27000 3 10 3 9.6
Liver 2700 6.6 -4.8 9 -5.3
13500 0.8 0.09 9.5 7
54000 4.6 8.4 5.1 9.7
Spleen 270 1.2 9.9 1.7 11.6
5400 7.9 0.2 8.9 4.8
13500 9.2 -8.7 9.8 -7.3
Lung 540 6.1 9.8 6.4 10.7
2700 8.6 -2.5 9.6 3
13500 6.5 9 8.6 11
Kidney 540 6 -7.9 9.5 -8.5
5400 5.2 -3.1 6.1 -3.9
13500 7.6 -10.8 9.1 -8.7
Large intestine 2700 12.4 -8.6 11.9 -1.4
13500 6.5 -9.4 10 -7.5
54000 4.1 3.4 7.1 2
Small intestine 5400 2.2 9 10.7 8.9
108000 8.4 1.1 9.7 2.3
216000 8.6 1.7 7.2 7.3
Stomach 13500 14.3 7.5 13.5 4.6
216000 13.1 -0.2 14.2 2.4
864000 12.1 -8.5 14.7 -4.8