Table 1.

Comparisons of Vasculature Parameters among Different Locations using Optical Coherence Tomography Angiography Imaging

Average Nasal (N) Temporal (T) Inferior (I) Superior (S) ANOVA Post Hoc
Superficial Layer P Value
Vessel density (%) 27.4±3.0 30.6±3.1 26.7±4.4 25.6±4.6 26.8±4.4 0.054
Vessel length density (%) 4.67±0.48 5.00±0.40 4.60±0.83 4.26±0.69 4.83±0.87 0.069
Vessel diameter index 17.2±0.6 18.0±0.8 17.0±0.4 17.6±1.2 16.3±1.1 0.003 N>S
Fractal dimension 1.333±0.034 1.353±0.028 1.329±0.060 1.309±0.058 1.341±0.060 0.32
Deep Layer
Vessel density (%)

23.0±2.1

25.8±3.2

24.6±3.0

20.9±3.5

20.6±4.1

0.003

N>S
Vessel length density (%) 3.88±0.35 4.49±0.56 4.42±0.62 3.41±0.68 3.19±0.66 <0.001 N>I,S T>I,S
Vessel diameter index 17.6±0.7 16.8±0.8 16.3±0.7 18.1±1.2 19.0±1.5 <0.001 N<S T<S,I
Fractal dimension 1.280±0.028 1.335±0.036 1.328±0.045 1.240±0.067 1.217±0.059 <0.001 N>S,I T>S,I

Data are mean ± standard deviation.

Significant differences in Tukey’s honestly significant differences after Bonferroni corrections are shown.