Table 6.
Technical and economic parameters of energy conversion technologies (Liu et al., 2010). COP stands for coefficient of performance.
Technology | Input | Output | ηconv | INV ($/kW) |
O&M ($/kW/yr) |
---|---|---|---|---|---|
Cold Air Retrieval | Electricity | Ventilation | 6 (COP) | 50 | 3 |
Refrigeration with Heat Recovery | Electricity | Refrigeration, Space Heating | 3, 2 (COP) | 100 | 5 |
Refrigeration without Heat Recovery | Electricity | Refrigeration | 3 (COP) | 70 | 4 |
Fluorescent Lighting | Electricity | lighting | 0.2 | 5 | 0.5 |
LED | Electricity | lighting | 0.8 | 10 | 1 |
Bakery A | Electricity | Bakery | 0.7 | 30 | 3 |
Bakery B | Electricity | Bakery | 0.75 | 40 | 4 |
Heating A | Heat | Space Heating | 0.85 | 30 | 3 |
Heating B | Heat | Space Heating | 0.9 | 40 | 4 |