Endoscopic ultrasound guided gallbladder drainage using lumen apposing metal stents

Author Type of study Year of publication Number of patients Technical success (%) Clinical success (%) Adverse events (%)
de la Serna-Higuera et al Retrospective 2013 13 86.4 100 18
Irani et al Retrospective 2015 15 93 100 13
Walter et al Prospective 2016 30 90 96 Not available
Law et al Retrospective 2016 7 100 100 0
Kahaleh et al Retrospective 2016 35 91.4 89 11
Irani et al Retrospective 2017 45 98 96 11
Dollhopf et al Retrospective 2017 75 98.7 95.9 10.7
Teoh et al Prospective 2017 59 100 100 23.7