Skip to main content
. 2018 Aug 31;315(5):H1486–H1494. doi: 10.1152/ajpheart.00301.2018

Table 4.

Reproducibility of endothelial function assessments in patients with cystic fibrosis

Between-Day Pre Visit 1 vs. Pre Visit 2
Variable Pre Visit 1 Pre Visit 2 t-test CV CV′ ICC r BA plot
Diameter, mm
    Baseline 3.07 (0.53) 3.04 (0.64) 0.558* 19.9* 0.01* 0.997, P < 0.01* 0.979, P < 0.01* X*
    Peak 3.32 (0.61) 3.21 (0.63) 0.576* 18.7* 0.02* 0.985, P < 0.01* 0.970, P < 0.01* X*
FMD, % 7.6 (4.1) 7.5 (4.3) 0.615* 52.0 2.07* 0.940, P < 0.01* 0.982, P < 0.01* X*
FMD (%)/shear (s-1, AUC) 0.16 (0.06) 0.15 (0.07) 0.507* 39.2 0.05* 0.854, P < 0.01* 0.825, P < 0.01* X*

Values are means (SD). Reproducibility was evaluated using t-test statistic (P value), coefficient of variation (CV = SD/mean × 100), CV′ [CV′ = (100 × SD)/(mean + 100)], intraclass correlation coefficient (ICC), Pearson’s correlation coefficient (r), and Bland-Altman (BA) plot. X in the BA cell indicates an acceptable plot. FMD, flow mediated dilation.

*

Acceptable reproducibility.