Skip to main content
. 2018 Dec 9;2018:6527549. doi: 10.1155/2018/6527549

Table 3.

Standard curves, linear range, correlation coefficient, LOD, and LLOQ of aconitine, mesaconitine, and hypaconitine in rat plasma.

Name Standard curves Linear range R2 LLOQ LOD
(ng/mL) (ng/mL) (ng/mL)
Aconitine y = 0.3651x + 0.0210 0.1-10 0.9997 0.1 0.025
Mesaconitine y = 0.7952x + 0.0218 0.1-10 0.9987 0.1 0.025
Hypaconitine y = 0.718x + 0.0605 0.1-10 0.9970 0.1 0.025