Table 4.
The Ea and k25 parameters for kcatCO2/KC, kcatO2/KO, kcatCO2/kcatO2, and KO/KC ratios
Method | Temperature range (°C) | Parameter | k 25 | E a |
---|---|---|---|---|
Radiolabel | 10–35 | k catCO2/KC | 0.09 ± 0.00 | –3.45 ± 3.94 |
MIMS | 10–25 | (s−1 Pa−1) | 0.10 ± 0.01 | 27.75 ± 3.38* |
25–40 | – | –0.41 ± 6.10 | ||
MIMS | 10–25 | k catO2/KO | 0.06 ± 0.00 | 75.93 ± 7.41* |
25–40 | (s−1 kPa−1) | – | 30.09 ± 0.70* | |
MIMS | 10–25 | k catCO2/kcatO2 | 2.55 ± 0.16 | –2.58 ± 6.73 |
25–40 | – | 15.10 ± 4.92* | ||
Radiolabel | 15–35 | K O/KC | 0.65 ± 0.11 | –46.20 ± 8.80* |
MIMS | 10–40 | (kPa Pa−1) | 0.71 ± 0.01 | –45.60 ± 2.57* |
The Ea parameters were tested to determine if they were significantly different from zero (t-test), where the * next to the Ea values indicates a P-value <0.05.