Skip to main content
. 2018 Nov 24;18(12):4124. doi: 10.3390/s18124124

Table 1.

Voltammetric immunosensors constructed on SPE and associated with flow analysis in different applications.

Analyte Transducer Detection Limit Sample Reference
Okadaic acid
(toxin)
SPCE modified with MBs 0.15 µg·mL−1 Mussel [46]
CEA
(tumor marker)
SPCE modified with CEA/colloidal Au/chitosan film 0.22 ng·mL−1
0.45 ng·mL−1
Serum [47]
HIgG
(biomarker)
SPCE modified with GO 1.70 ng·mL−1 Urine [48]
Isoproturon
(herbicide)
SPCE 0.84 ng·mL−1 Soil [50]
2,4-D
(herbicide)
Gold-SPE modified with cysteamine 0.12 µg·mL−1 Water and food [51]
Biotin
(vitamin)
SPCE 10−14 mol·L−1 Clinical [52]
Botrytis cinerea
(fungus)
SPCE modified with MWCNT 0.02 µg·mL−1 Fruit [53]

Abbreviations: CEA = carcinoembryonic antigen; HIgG = human immunoglobulin G; GO = graphene oxide; 2,4-D = 2,4-dichlorophenoxyacetic acid; MWCNT = multi-walled carbon nanotubes.