Table 3.

Defect classification follow-up priority, F, scheme defined as the product of the defect category, C, and directionality distribution, D. If F = 0, then a classification is assigned for the weld feature; if F = 1, then a low priority is assigned for follow-up (yellow-shaded cell); if F = 2, then a medium follow-up priority is required (orange-shaded cell); if F ≥ 3, then a high follow-up priority is required for signals from defects (red-shaded cell) [112,185].

Follow-up Priority
F = C × D
Defect Category, C
1 2 3
Directionality distribution
(D)
0 0 0 0
1 1 2 3
2 2 4 6