Skip to main content
. 2018 Dec 4;18(12):4263. doi: 10.3390/s18124263

Table 5.

Properties of most relevant plasmonic PCF sensors.

Application PCF Type Wavelength (nm) Sensitivity Resolution Ref.
Refractive index IG-PCF 500 to 1500 873 dB/RIU 3×105 RIU [201]
Refractive index IG-PCF 750 to 1750 2520 nm/RIU 3.97×105 RIU [202]
Refractive index IG-PCF 500 to 1010 9000 nm/RIU 1.11×105 RIU [203]
Refractive index IG-PCF 900 to 1200 10,000 nm/RIU 106 RIU [203]
Refractive index HC-PBF 560 to 610 14,240 nm/RIU 7.02×105 RIU [216]
Refractive index HC-PBF 1330 5500 nm/RIU NA [98]
Refractive index SCF 400 to 700 227 nm/RIU NA [220]
Refractive index SCF 1550 8360 rad/RIU 2.1×106 RIU [221]
Temperature IG-PCF 400–500 2.7 nm/°C NA [214]
Temperature IG-PCF 800–1100 5 nm/°C NA [219]
Temperature IG-PCF 1550 0.315 dB/°C NA [222]
Temperature HC-PBF NA 0.72 nm/°C 1.39×102 °C [223]
Temperature HC-PBF 550–900 3.08 nm/°C 1.325×102 °C [224]
Temperature HC-PBF NA 2.8×105 RIU [225]
Pressure IG-PCF 400–800 32.89 nm/N NA [226]
Biolayer thickness IG-PCF 600–750 2.3 nm/nm 0.044 nm [227]