Skip to main content
. Author manuscript; available in PMC: 2018 Dec 28.
Published in final edited form as: Phys Med Biol. 2018 Nov 20;63(22):225020. doi: 10.1088/1361-6560/aaebc9

Table 2.

Physicians’ scoring of the reconstructed image quality in figure 12 by the different reconstruction methods.

Dose Physician FBP Gaussian Huber TP RATP
1/8 #1 5 6 5 7 8
#2 5 6 6 8 9
#3 4 6 5 8 9
Average 4.67 6 5.33 7.67 8.67

1/16 #1 2 4 3 5 6
#2 2 4 3 4 5
#3 2 3 4 4 5
Average 2 3.67 3.33 4.33 5.67