TABLE II.

Kinetic Parameter Values Estimated by Classic CM and IQML With Algorithms Being Initialized by the Ground Truth

Ground truth parameter values SNR=20dB SNR=15dB SNR=10dB
CM IQML CM IQML CM IQML
Scenario 1 Kstrans = 0.03 /min 0.048 0.074 0.048 0.074 0.047 0.074
kep,s =0.1 /min 0.227 0.170 0.231 0.193 0.228 0.186
Kftrans = 0.03 /min 0.094 0.111 0.084 0.106 0.085 0.107
kep,f =0.5 /min 0.920 0.496 0.810 0.515 0.827 0.509
Scenario 2 Kstrans = 0.03 /min 0.051 0.038 0.050 0.040 0.049 0.040
kep,s =0.1 /min 0.266 0.154 0.257 0.163 0.253 0.156
Kftrans = 0.05/min 0.125 0.058 0.124 0.063 0.134 0.067
kep,f =1.2 /min 1.596 0.506 1.542 0.545 1.708 0.572
Scenario 3 Kstrans = 0.06/min 0.095 0.160 0.093 0.159 0.092 0.161
kep,s =0.5 /min 0.758 0.631 0.745 0.624 0.756 0.633
Kftrans = 0.05/min 0.134 0.200 0.132 0.200 0.130 0.200
kep,f =l.2/min 1.729 1.144 1.730 1.144 1.724 1.143
Scenario 4 Kstrans = 0.05/min 0.101 0.119 0.097 0.128 0.098 0.128
kep,s= 0.6 /min 1.045 0.849 0.998 0.849 1.001 0.850
Kftrans = 0.08/min 0.168 0.181 0.155 0.191 0.157 0.189
kep,f= 1.5 /min 2.106 1.418 1.960 1.422 1.965 1.422