Skip to main content
. 2018 Oct 6;70(Suppl 3):S347–S352. doi: 10.1016/j.ihj.2018.09.012

Table 2.

Procedural details.

Anesthesia General: 15 (60%)
Conscious sedation: 10(40%)
Access route Femoral: 25 (100%)
Use of transesophageal 16/25 (64%)
Echocardiogram
LV wire Amplatz super/extrastiff wire: 17/25 (64%),
Confida wire: 6/25 (24%),
Lunderquist wire: 2/25 (8%)
Preprocedure vascular cutdown Nil
Preprocedure proglide 25/25 (100%)
Predilatation Evolut R/Core valve: 5
Sapien 3: 5
Valve type Evolut R: 15 (60%)
SAPIEN 3: 7 (28%)
Core valve: 2 (8%)
Balloon-expandable study valve: 1 (4%)
Valve size 23 mm: 6/25 patients (24%)
26 mm: 11/25 patients (44%)
29 mm: 8/25 patients (32%)
Paravalvular leak Severe PVL: Nil
Moderate PVL: 3 (12%)
Mild PVL: 11 (44%)
No PVL: 11 (44%)
Postdilatation required 3 (12%)
Immediate postprocedure mean LV ejection fraction 55.4 ± 9.4%
Immediate postprocedure mean aortic valve gradient 8.5 ± 4.9 mmHg
Procedural success 25/25 (100%)

Data are presented as mean ± SD or as number and percentage.

LV, left ventricle; PVL, paravalvular leak.