Skip to main content
. 2018 Dec 11;14(4):383–390. doi: 10.5114/aic.2018.79868

Table II.

Angiographic finding and primary percutaneous coronary intervention

Parameter Normal reflow (n = 3333) No-reflow (n = 471) P-value
Multivessel disease (%) 1365 (41) 279 (59.2) < 0.001
Infarct related coronary artery (%): 0.925
 Left main artery 48 (1.4) 6 (1.3)
 Left ascending artery 1586 (47.6) 220 (46.7)
 Left circumflex artery 1129 (33.9) 162 (34.4)
 Right artery 570 (17.1) 83 (17.6)
Preintervention TIMI-flow (%): < 0.001
 0 2325 (69.8) 357 (75.7)
 1 356 (10.7) 72 (15.4)
 2 497 (14.9) 34 (7.2)
 3 155 (4.6) 8 (1.7)
Thrombus burden (%): < 0.001
 Low thrombus burden 1873 (56.2) 200 (42.5)
 High trombus burden 1460 (43.8) 271 (57.5)
Lenght of target lesion [mm] 13.5 ±12.2 19.3 ±8.6 < 0.001
Reference vessel diameter [mm] 3.2 ±1.2 2.6 ±0.8 < 0.001
Reperfusion method (%): < 0.001
 Balloon dilation 396 (11.9) 65 (13.8)
 Balloon predilation following stent implantation 2395 (71.9) 368 (78.2)
 Stent implantation 542 (16.2) 38 (8)
Thrombus aspiraton (%) 137 (4.1) 27 (5.7) 0.170
Use of tirofiban (%) 854 (25.6) 219 (46.5) < 0.001

Data are presented as mean. TIMI – thrombolysis in myocardial infarction.