Table 2. Approximation of axial stiffness from the slope term of the force/displacement relationship for anterior and posterior corneal stroma.

Subject Eye R2a R2p ka kp ka/kp
1 OD 0.99 0.99 0.0185 0.0160 1.156
OS 0.99 0.99 0.0156 0.0129 1.209
2 OD 0.99 0.99 0.0180 0.0161 1.118
OS 0.97 0.98 0.0173 0.0137 1.263
3 OD 0.99 0.99 0.0165 0.0144 1.146
OS 0.99 0.99 0.0180 0.0157 1.146
4 OD 0.99 0.99 0.0183 0.0153 1.196
OS 0.98 0.98 0.0182 0.0161 1.130
5 OD 0.97 0.96 0.0121 0.0120 1.008
OS 0.98 0.99 0.0179 0.0168 1.065
6 OS 0.98 0.99 0.0238 0.0227 1.048
7 OS 0.95 0.95 0.0129 0.0114 1.132
8 OD 0.93 0.94 0.0110 0.0101 1.089
OS 0.98 0.99 0.0105 0.0096 1.094
9 OS 0.97 0.98 0.0176 0.0161 1.093
10 OD 0.96 0.97 0.0092 0.0084 1.095
OS 0.99 0.99 0.0113 0.0102 1.108
mean 0.98 0.98 0.0157 0.0140 1.123
standard deviation 0.02 0.02 0.0039 0.0035 0.062