Skip to main content
. 2018 Nov 27;15(12):2666. doi: 10.3390/ijerph15122666

Table 2.

Parameter limits are according to DIN 19643-1 [21]. Limits are only valid for pool water and filtrate (not for balance tank water and filter backwash water).

Microbial Parameter Method Parameter Limits Chemical Parameter Method Parameter Limits
Total heterotrophic counts at 36 °C TrinkwV, appendix 5 <100 CFU/mL THM (mg/L) DIN EN ISO 10301:1997 <0.02
Escherichia coli DIN EN ISO 9308-2 <1 CFU/100 mL Bromate (mg/L) DIN EN ISO 15061 <2.0
Pseudomonas aeruginosa DIN EN ISO 16266 <1 CFU/100 mL Chlorate and chlorite (mg/L) LC-MS <30
Al (mg/L) DIN EN ISO 11885 <0.05
Fe (mg/L) DIN EN ISO 11885 <0.02
pH DIN EN ISO 10523 6.5–7.5
KS4.3 (mmol/L) DIN 38409-1 >0.7
Nitrate (mg/L) EN ISO 10304:1995 <20
Ox. (mg/L) DIN EN ISO 8467 <0.75
Redox (mV) DIN 38404-6 >750
Free chlorine (mg/L) DIN EN ISO 7393-1 0.3–0.6
Bound chlorine (mg/L) DIN EN ISO 7393-1 <0.2

THM: Trihalogenmethane; LC-MS: Liquid chromatography–mass spectrometry.