Table 2. Intraobserver and Interobserver Variabilities in and Agreements for SWT and Imaging Biomarkers.

Parameters Intraobserver Interobserver
SWT (%)
 SWT at baseline −0.6 ± 5.3 (rIC = 0.93) 0.5 ± 6.2 (rIC = 0.92)
 SWT at follow-up −0.8 ± 5.9 (rIC = 0.92) 0.3 ± 7.0 (rIC = 0.90)
 Improved SWT −0.2 ± 4.4 (rIC = 0.95) −0.1 ± 4.6 (rIC = 0.94)
ECV (%) 0.2 ± 2.8 (rIC = 0.97) −0.4 ± 3.0 (rIC = 0.97)
TEI (transmurality, %) −0.7 ± 6.3 (rIC = 0.95) −1.0 ± 7.2 (rIC = 0.93)
RIM (mm) −0.1 ± 0.9 (rIC = 0.93) 0.3 ± 1.1 (rIC = 0.92)

Data are presented as differences (intraclass correlation coefficient rIC). ECV = extracellular volume fraction, RIM = unenhanced rim thickness, SWT = segmental wall thickening, TEI = transmural extent of infarction