Skip to main content
. 2018 Dec 16;11(4):138. doi: 10.3390/ph11040138

Table 3.

Enthalpy change (ΔH) values determined for each DSC scan during in vitro experiments on IDE-loaded SLN interactions with MLV liposomes and ΔH difference between scan 1 and scan 9 (ΔH1–9).

Sample ΔH (J/mol) ΔH1–9 (J/mol)
scan 1 scan 2 scan 3 scan 4 scan 5 scan 6 scan 7 scan 8 scan 9
A1 27.06 26.38 24.12 24.58 24.11 24.04 23.57 23.10 23.04 4.02
A2 27.58 24.25 24.25 23.57 23.65 23.93 23.22 23.36 23.65 3.93
B1 29.69 29.09 26.75 23.30 23.52 22.53 21.24 20.84 20.88 8.81
B2 30.01 30.34 25.93 25.38 24.38 24.22 24.49 24.53 24.34 5.67
B3 28.40 28.39 26.42 26.12 26.50 25.50 24.61 24.11 24.39 4.01
C1 28.32 27.90 26.43 21.63 20.18 17.96 15.99 15.23 15.13 13.19
C2 27.16 26.70 24.77 21.98 20.56 19.25 18.39 17.58 17.48 9.68
C3 27.53 24.56 23.65 21.89 20.36 19.54 18.65 18.70 18.79 8.74