Skip to main content
. Author manuscript; available in PMC: 2020 Jan 1.
Published in final edited form as: Retina. 2019 Jan;39(1):69–78. doi: 10.1097/IAE.0000000000001909

Table 3.

Mean Change in RNFL Thickness Measurements from Baseline to 1 and 2 Years

RNFL Quadrant
(µm)
Ranibizumab
Mean ± SD*
Prompt PRP
Mean ± SD
Adjusted Mean Difference†
(95%CI)
P-value
1 year N = 73 N = 57
 Inferior −12.4 ± 17.7 −2.7 ± 14.1 −9.7 (−14.8, −4.6) <0.001
 Superior −9.3 ± 12.1 −3.5 ± 14.3 −5.7 (−9.1, −2.3) <0.001
 Nasal −7.9 ± 9.6 −1.3 ± 10.0 −7.3 (−9.9, −4.7) <0.001
 Temporal −7.7 ± 11.4 +1.8 ± 11.1 −9.4 (−12.6, −6.2) <0.001
 Average −9.6 ± 10.8 −1.9 ± 12.3 −7.4 (−10.0, −4.9) <0.001
2 years N = 74 N = 66
 Inferior −14.8 ± 18.8 −6.5 ± 16.8 −7.6 (−11.6, −3.7) <0.001
 Superior −11.9 ± 14.7 −6.4 ± 16.0 −4.5 (−8.4, −0.6) 0.023
 Nasal −8.8 ± 10.4 −3.1 ± 10.0 −5.5 (−8.0, −2.9) <0.001
 Temporal −7.4 ± 13.0 +0.8 ± 13.3 −7.6 (−11.4, −3.8) <0.001
 Average −10.9 ± 11.7 −4.3 ± 11.6 −4.9 (−7.2, −2.6) <0.001

PRP= panretinal photocoagulation; RNFL = retinal nerve fiber layer

*

Truncated to ± 3 standard deviation from the mean; inferior, 3 eyes; superior, 3 eyes; nasal, 1 eye; temporal, 2 eyes; average, 2 eyes.

†

Adjusted mean difference, confidence intervals obtained from ANCOVA model adjusting for baseline RNFL thickness measurements, central subfield thickness and laterality