Table 4. Logistic regression analysis for factors associated with patent false lumen after one year (N = 95).

Variables (Number) n/N (%) Univariate Multivariate
Crude OR(95%CI) p Adjusted OR(95%CI) p
Patent false lumen (total 50)
Tear resection 32/68(47.1%) 0.44(0.18–1.13) 0.088 #
Root reconstruction 11/16(68.8%) 2.26(0.72–7.09) 0.164 #
Total arch replacement 8/32(25.0%) 0.17(0.06–0.43) 0.000 0.31(0.10–0.94) 0.038
Descending aorta stent grafting 7/37(18.9%) 0.08(0.03–0.22) 0.000 0.11(0.04–0.32) 0.000
Surgical groups
    I 37/48(77.1%) reference #
    II 6/10(60.0%) 0.45(0.11–1.87) 0.269
    III 2/22(9.1%) 0.03(0.01–0.15) 0.000
    IV 5/15(33.3%) 0.15(0.04–0.53) 0.003

# Not included in multivariate model; CI: confidence intervals; OR: odds ratio