Skip to main content
. Author manuscript; available in PMC: 2019 Oct 1.
Published in final edited form as: Pediatr Neurol. 2018 Jul 25;87:70–74. doi: 10.1016/j.pediatrneurol.2018.07.002

Table 2:

Performance of HINE vs. HINE or Asymmetry score

HINE<63 HINE <63 OR Asymmetry >5
Parameter: Value 95% CI Value 95% CI
Sensitivity 0.7297 (0.62, 0.82) 0.9189 (0.83, 0.96)
Specificity 1.0 (0.95, 1.0) 1.0 (0.95, 1.0)
PPV 1.0 (0.93, 1.0) 1.0 (0.95, 1.0)
NPV 0.7872 (0.69, 0.86) 0.925 (0.84, 0.97)
AUC 0.8649 (0.81, 0.92) 0.9595 (0.93, 0.99)

HINE: Hammersmith Infant Neurological Exam; PPV: positive predictive value for CP; NPV negative predictive value for CP; AUC area under the curve; CI: confidence interval