Skip to main content
. 2018 Dec 7;19(12):3937. doi: 10.3390/ijms19123937

Table 3.

The polymerization shrinkage and degree of conversion in studied Bis-GMA/TEGDMA/AgNP nanocomposites.

Sample Polymerization Shrinkage (%) Degree of Conversion (%)
Ph0 8.37 ± 0.58 1 69.8 ± 6.0 31,32
Ph25 8.22 ± 0.60 2,6 67.2 ± 7.0 33
Ph50 8.01 ± 0.70 3,7 64.8 ± 4.6 34,35,f
Ph100 7.41 ± 0.62 4,6 60.2 ± 4.2 g
Ph150 6.95 ± 0.96 5,7,a,b 54.8 ± 5.6 31,34,h
Ph250 5.44 ± 0.53 1–5,c,d 50.2 ± 7.5 32,33,35,i,j
RT0 8.39 ± 0.60 8,9 69.6 ± 5.4 36,39,k
RT25 8.13 ± 0.70 10 68.0 ± 4.9 37,40
RT50 7.99 ± 0.62 11 66.8 ± 4.7 41,l
RT100 7.84 ± 0.44 12 65.4 ± 7.2 38,42
RT150 7.77 ± 0.78 13,a 61.4 ± 7.2 m
RT250 7.66 ± 0.73 14,c 60.2 ± 6.3 j,n
RT500 7.41 ± 0.62 8,15 56.2 ± 7.7 36–38,o
RT1500 5.34 ± 0,59 9–15,e 52.0 ± 9.0 39–42,p
T0 8.50 ± 0.50 16,23 78.2 ± 5.5 43,k
T25 8.37 ± 0.43 17,24 78.0 ± 5.7 44
T50 8.28 ± 0.57 18,25 78.2 ± 5.4 45,f,l
T100 8.19 ± 0.48 19,26 77.4 ± 7.0 46,g
T150 8.13 ± 0.69 20,27,b 76.8 ± 7.0 47,h,m
T250 8.11 ± 0.51 21,28,d 76.6 ± 7.2 48,i,n
T500 8.01 ± 0.70 22,29 73.8 ± 4.9 49,o
T1500 7.15 ± 0.74 16–22,30,e 70.4 ± 7.4 50,p
T5000 5.01 ± 0.99 23–30 43.6 ± 7.8 43–50

1–50p < 0.05—statistically significant results within the nanocomposite series. a–p p < 0.05—statistically significant results between nanocomposites, having the same AgNP content, but obtained in different polymerization modes.