Characteristic quantiles represented as mean value ± standard deviation (n = 3) of the determined RTD for a constant SFL = 0.014.

m˙ [kg h−1] n [min−1] TBarrel 3–6 [°C] Screw Elements t10 [s] t50 [s] t90 [s]
2.4 100 150 standard 140.4 ± 2.7 247.4 ± 7.6 486.4 ± 12.5
reduced 163.4 ± 6.5 314.4 ± 9.5 664.8 ± 27.0
3.6 150 150 standard 90.2 ± 1.3 168.1 ± 6.4 418.6 ± 7.6
reduced 102.7 ± 0.8 207.8 ± 2.3 483.1 ± 13.0
4.8 200 150 standard 63.9 ± 1.3 120.0 ± 5.2 317.3 ± 35.7
reduced 74.5 ± 0.2 152.0 ± 4.2 371.6 ± 32.3
2.4 100 165 standard 143.3 ± 1.9 238.1 ± 13.3 454.3 ± 12.2
reduced 169.3 ± 3.2 335.6 ± 10.9 658.1 ± 13.7
2.4 100 180 standard 149.4 ± 4.5 240.4 ± 9.2 439.1 ± 45.5
reduced 177.9 ± 0.2 346.7 ± 31.3 698.2 ± 76.4