Conditions and parameters of the argon-ion laser, supercontinuum fiber laser, Nd:YAG laser, and CO2 fractional laser used when measuring laser-induced microbubble (MB) disruption.

Laser Type Argon Ion Laser Supercontinuum Fiber Nd:YAG CO2 Fractional
Wavelength (nm) 515 1064 532 10,600
Mode of operation Continuous Pulsed Pulsed Pulsed
Energy (mJ) n/a n/a 380 1.3
Output power (mW) 10.8 10.8 n/a n/a
Repetition rate n/a 80 MHz 5 Hz Single
Radiation repetitions (in vivo) n/a n/a n/a Seven times
Radiation times/repetitions (in vitro) 60, 120, or 180 s 60, 120, or 180 s 60, 120, or 180 s One, three, or seven times
MB dilution Fivefold Fivefold Five- or tenfold Tenfold
Average temperature increase (°C) 0.7 1.0 0.86 or 0.23 1.1