Skip to main content
. 2019 Jan 5;17:10. doi: 10.1186/s12967-018-1750-x

Table 2.

MC system vs. Harvest centrifugation system; comparison 2

Marrow cellution Harvest system
TNCs/mL
× 106
CD34+/mL
× 103
CD117+/mL
× 103
TNCs/mL
× 106
CD34+/mL
× 103
CD117+/mL
× 103
Patient 1 23.1 235 348 15.7 91.2 89.7
Patient 2 15.3 135 84.4 28.3 164 76.5
Patient 3 16.4 177 193 44.8 125 89.6
Patient 4 44.1 423 450 55.8 447 463
Patient 5 22.1 315 282 53.7 258 183
Average 24.2 ± 11.6* 257 ± 115 272 ± 141 39.7 ± 17.2 217 ± 143 180 ± 164

Levels of TNCs, CD34+, and CD117+ cells in MC aspirates and Harvest bone marrow concentrates taken from contralateral iliac crest draws in the same patient. (* p < 0.05)