Skip to main content
. 2018 Jun 25;47(8):20170325. doi: 10.1259/dmfr.20170325

Table 3.

Average of diameter, height, depth and volume differences from the gold-standard according to location, software and voxel size in mm

Location Diameter
(p < 0.05)
Height
(p > 0.05)
Depth
(p > 0.05)
Volume
(p < 0.05)
Cervical 0.0004 −0.0006 0.0293 −0.0005
Apical 0.0079 −0.0004 0.0304 −0.0120
Software Diameter
(p = 0.003)
Height
(p = 0.00)
Depth
(p = 0.08)
Volume
(p = 0.01)
3D-Doctor −0.0035 −0.0078 0.0348 −0.0068
ITK-SNAP 0.0096 0.0020 0.0222 0.0232
OsiriX 0.0017 −0.0052 0.0282 0.0223
Planmeca 0.0081 0.0090 0.0341 −0.0625
Voxel size Diameter
(p = 0.084)
Height
(p = 0.003)
Depth
(p = 0.09)
Volume
(p = 0.720)
0.075 mm −0.0003 −0.0069 0.0328 −0.0009
0.1 mm 0.0056 0.0042 0.0248 −0.0101
0.15 mm 0.0091 0.0045 0.0325 −0.0015
0.2 mm 0.0015 −0.0039 0.0291 −0.0111
a

Average of difference from the gold standard in mm.

b

Average of difference from the gold standard in mm³.