Skip to main content
. 2019 Jan 2;15:16–29. doi: 10.3762/bjoc.15.2

Table 1.

Summary of fitted parameters. Synthetic data were generated as described in the text and then fit to derive estimates of steady state kinetic parameters using different equations and different means of data fitting. Here we list the methods for fitting and the chosen fitted parameters for each method. The values for kcat, Km and kcat/Km are shown. Values in brackets were calculated from the other parameters. For example, in the first row, kcat/Km was calculated from kcat and Km, whereas in the second row, Km was calculated from estimates of kcat and kcat/Km. Standard error estimates for calculated parameters were obtained by propagation of errors as described in the text. Note that the fitted parameters need not reproduce the input parameters used to generate synthetic because of the added errors and the limited set of data. A more complete data set with lower errors would return the input parameters.

method fitted parameters kcat (s−1) Km (μM) kcat/Km (μM−1s−1)

equations kcat and Km 58.6 ± 25 44.4 ± 31 [1.32 ± 1.08]
kcat and kSP 58.7 ± 25 [44.4 ± 23] 1.32 ± 0.37

simulation kcat and Km 57.2 ± 5.9 27.2 ± 5.1 [2.11 ± 0.45]
kcat and kSP 57.3 ± 6.1 [27.8 ± 4.1] 1.62 ± 0.21

simulation full reaction kcat and Km 54.3 ± 4.9 23.6 ± 4.0 [2.30 ± 0.44]
kcat and kSP 55.2 ± 3.9 [24.9 ± 2.2] 2.22 ± 0.12

input values 50 20 2.5