Skip to main content
. 2018 Dec 25;24(1):71. doi: 10.3390/molecules24010071

Table 5.

Intra-day and inter-day precision and accuracy of CPS, RNG, and RNC in rat plasma (n = 6).

Analytes QC Concentration
(ng/mL)
Intra-Day Inter-Day
Actual Conc.
(ng/mL)
Precision
(RSD, %)
Accuracy
(RE, %)
Actual Conc.
(ng/mL)
Precision
(RSD, %)
Accuracy
(RE, %)
CPS 20 19.6 ± 0.6 3.1 2.0 19.8 ± 1.9 9.6 1.0
125 124.8 ± 7.3 5.8 0.2 124.8 ± 6.2 5.0 0.2
500 504.7 ± 24.2 4.8 −0.9 494.8 ± 17.9 3.6 1.0
RNG 20 19.2 ± 1.1 5.7 4.0 18.8 ± 1.7 9.0 6.0
125 123.2 ± 5.8 4.7 1.4 125.4 ± 2.19 1.7 −0.3
500 504.7 ± 21.4 4.2 −0.9 498.6 ± 18.2 3.7 0.3
RNC 20 19.3 ± 1.0 5.2 3.5 18.7 ± 1.9 10.1 6.5
125 125.8 ± 4.9 3.9 −0.6 122.4 ± 10.5 8.6 2.1
500 496.9 ± 13.6 2.7 0.6 505.8 ± 13.5 2.7 −1.2

CPS: complanatuside; RNG: rhamnocitrin 3-O-β-glc; RNC: rhamnocitrin.RE: relative error.