Table 2.

Accuracy evaluation using different ε for airborne laser scanning data using X, Y, Z fields.

Test ε Correct Detection Under-Segmentation Over-Segmentation Missed Accuracy
T1 0.6 149 40 81 63 45%
T2 0.7 176 36 65 56 53%
T3 0.8 233 17 36 47 70%
T4 0.8114 251 21 15 46 75%
T5 0.9 201 33 36 63 60%
T6 1.0 210 29 26 68 63%
T7 1.1 182 51 7 93 55%