Skip to main content
. 2017 May 19;1(1):10–14. doi: 10.1016/j.jses.2017.03.004

Table VII.

Multivariable logistic regression for the probability of blood transfusion in the population of total shoulder arthroplasty patients

OR 95% CI for OR P value
Age, y 1.134 0.908-1.417 .268
Gender 27.860 0.298-2604.843 .151
Surgery duration, h 0.026 0.001-1.308 .068
EBL, 100 units 7.166 7.039-7.296 .031*
Total drain output, mL 0.974 0.944-1.005 .105
Preoperative Hgb level 0.008 0.000-0.526 .024*

OR, odds ratio; CI, confidence interval; EBL, estimated blood loss; Hgb, hemoglobin.