Skip to main content
. 2019 Jan 21;19:27. doi: 10.1186/s12886-018-0997-6

Table 1.

Agreement analysis between the two sets of segmented Color and IR images based on obtained retinal vascular parameters

Parameter Mean Difference LOA p value * p value** κ ***
Ground Truth Set 1 FD −0.003 0.053 to − 0.058 0.63 0.88 0.59
VBR (%) 0.001 0.030 to −0.029 0.79 0.90 0.42
ABA 1.2 13.3 to −10.9 0.34 0.73 0.28
TAC − 5.1 17.7 to −27.9 0.05 0.14 0.05
ST −0.005 0.023 to −0.033 0.10 0.80 0.20
Ground Truth Set 2 FD 0.00 0.060 to −0.059 0.96 0.28 0.25
VBR (%) 0.00 0.027 to −0.027 0.97 0.64 0.29
ABA 1.50 15.0 to −12.1 0.31 0.11 0.22
TAC 0.90 22.0 to −20.3 0.68 0.78 0.04
ST 0.003 0.079 to −0.073 0.69 0.13 0.25

*p-value of one sample t-tests (comparing between mean difference and zero value) to indicate presence of systemic bias

**p-value of Regression Analysis to indicate presence of proportional bias

***κ Cohen’s kappa value to indicate the level of agreement color and IR images