Table 2.
Pearson correlation coefficients (r) among the values of Tb measures derived from postregistered micro‐CT and MDCT images of cadaveric ankle specimens from matching VOIs (n = 250) of diameter 5.25 mm. Mean values of Tb measures observed for the two scanners are shown. See Table 1 for definitions of Tb measures
Tb measure | Correlation coefficients (r) | micro‐CT (mean value) | MDCT (mean value) |
---|---|---|---|
vBMD (mg/cm3) | 0.88 | 1158 | 993 |
tBMD (mg/cm3) | 0.86 | 194 | 120 |
Tb.NA (cm2/cm3) | 0.92 | 0.10 | 0.07 |
Tb.PW (μm) | 0.87 | 541 | 861 |
Tb.PR (no unit) | 0.85 | 2.85 | 7.02 |
Tb.Th (μm) | 0.71 | 133 | 160 |
Tb.Sp (μm) | 0.81 | 348 | 468 |
EI (no unit) | 0.63 | 0.20 | 0.67 |
SMI (no unit) | 0.78 | 0.76 | 2.23 |
For this experiment, MDCT images from the Siemens Flash scanner were used.