Neutrophil transition from rolling to arrest on E-selectin/ICAM-1 and HMVECs. E-selectin/ICAM-1 substrates or inflamed HMVECs were treated with EC-SEAL (30 µM) or GMI-1070 (6.5 µM). Neutrophils were added to the inlet reservoir of a microfluidic device and a syringe pump applied negative pressure at the outlet to create a shear stress of 2 dynes/cm2 in the flow chamber. Positional tracking and manual counts allowed for distinguishing between rolling vs. arrested vs. migrated neutrophils. On E-selectin/ICAM-1 substrates, EC-SEAL significantly reduced neutrophil transition to arrest compared to vehicle control, while neither treatment reduced migration of arrested neutrophils. On inflamed HMVECs, both EC-SEAL and GMI-1070 reduced neutrophil transition to arrest and subsequent migration. n = 4, p < 0.05.