Table 1.
The nominal and averaged measured parameters associated with the electron beam (before and after IFEL acceleration), the CO2 laser, and the ICS X-rays are presented here for convenience.
Parameter | Unit | Value | |
---|---|---|---|
Electron beam | Initial | After IFEL | |
Energy, Ue | MeV | 52.0 | 81.7 |
Energy spread, | — | <0.005 | 0.028 |
Charge, Qe | pC | 250 | 100 |
Bunch length, σt | ps | 3 | 2.5 |
Normalized emittance, εn | mm-mrad | 2.3 ± 0.1 | 2.4 ± 0.15 |
Transverse size at ICS IP, σx × σy | µm | 140 × 170 (±10) | 140 × 170 (±10) |
Repetition rate | Hz | 1 | 0.008 |
CO 2 Laser Pulse | |||
Central wavelength, λL | µm | 10.3 | |
Energy, UL | J | 1.02 ± 0.12 | |
Pulse length, σt | ps | 2.5 | |
Transverse size at ICS IP, w0 | µm | 150 | |
Repetition rate | min | 1–2 | |
ICS X-rays | |||
Central energy | keV | 11.6 | |
Photons per shot | # | 1.21 (±0.63) × 106 | |
Opening angle, θ ~ 1/γ | mrad | 3.4 ± 0.1 |