Skip to main content
. 2019 Jan 28;7:12. doi: 10.1186/s40168-019-0626-5

Table 3.

The number of false positive and false negative contigs generated by each assembler for (a) mock community A and (b) mock community B along with the sensitivity rates for each

False positives False negative True positive No. of contigs returneda Sensitivity
A
 ABySS (k-mer 63) 52 4 8 61 66.67
 ABySS (k-mer 127) 50 6 6 56 50.00
 CLC 1143 0 12 1299 100.00
 Geneious 53 0 12 65 100.00
 IDBA UD 0 0 12 12 100.00
 MEGAHIT 0 0 12 13 100.00
 MetaVelvet 0 3 9 26 75.00
 MIRA 0 0 12 89 100.00
 Ray Meta 0 0 12 12 100.00
 SOAPdenovo2 2 0 12 23 100.00
 SPAdes 0 0 12 14 100.00
 SPAdes meta 0 0 12 14 100.00
 SPAdes sc 1513 0 12 1527 100.00
 SPAdes sc careful 0 0 12 15 100.00
 Velvet 0 3 9 26 75.00
 VICUNA 4969 0 12 5385 100.00
B
 ABySS (k-mer 63) 60 4 8 69 66.67
 ABySS (k-mer 127) 132 6 6 139 50.00
 CLC 450 0 12 505 100.00
 Geneious 14 0 12 30 100.00
 IDBA UD 0 0 12 12 100.00
 MEGAHIT 0 0 12 14 100.00
 MetaVelvet 0 1 11 24 91.67
 MIRA 94 1 11 157 91.67
 Ray Meta 0 0 12 13 100.00
 SOAPdenovo2 2 2 10 27 83.33
 SPAdes 0 0 12 13 100.00
 SPAdes meta 0 0 12 14 100.00
 SPAdes sc 593 0 12 607 100.00
 SPAdes sc careful 0 0 12 14 100.00
 Velvet 0 1 11 24 91.67
 VICUNA 0 0 12 15 100.00

a12 in community