Skip to main content
. 2019 Feb;14(1):74–87.

Table 2.

Electrode Placement and MVIC/strength test positions.

EMG collected Electrode Location MVIC/Strength test position
Upper Trapezius A mark was made on the skin at the midpoint on a line joining the C7
spinous process and tip of the posterior lateral angle of the acromion.
The electrodes were placed over a point 1/2 distance between this point
and the posterior lateral angle of the acromion37
Abduction: The participant abducted his/her arm to 90 ° with thumb pointing up.
The hand held dynamometer was applied just proximal to the elbow with the participant sitting upright.
The participant abducted his/her arm up against resistance applied through the humerus
Lower Trapezius The arm was elevated in abduction to 125 ° and the electrodes were placed at the
midpoint from the T7 spinous process to the inferior angle of the scapula in line
with muscle fibers obliquely superior and laterally38
Prone Elevation: In a prone position, the participant abducted his/her arm to 125 ° with thumb up.
Subject was asked to push up against the hand held dynamometer that was placed
on distal arm just proximal to the radial styloid.
Serratus Anterior With the arm elevated to 125 ° the electrodes
were places over the 7th intercostal space, just anterior
to the fibers of the latissimus dorsi in line with the serratus
anterior muscle fibers36
Flexion: With subject seated, resistance was applied with
the hand held dynamometer to distal arm proximal to
the wrist in a perpendicular direction with the humerus elevated
to 125 ° in the sagittal plane