Skip to main content
. Author manuscript; available in PMC: 2019 Feb 1.
Published in final edited form as: Space Sci Rev. 2017 Dec 13;214(1):19. doi: 10.1007/s11214-017-0439-4

Table 14.

Gas trapping efficiencies of the SRC filter

Compound Integration range (cm−1) Filter efficiency (%)
Ethanol 3534–3345 99.37
Benzene (4 bands) 3110–2998 >94
Hexane+ethanol+acetone 2999–2845 >98.5
CO 2157–2129 84
Benzene 1988–1960 >90
Benzene 1843–1813 >99.2
Acetone 1731–1698 99.05
Benzene 1488–1477 98
Mostly ethanol 1477–1407 99.4
Hexane+ethanol+acetone 1397–1348 99.27
Hexane+ethanol+acetone 1266–1216 99.4
Ethanol+acetone+benzene 1106–1024 98.7
Acetone+ethanol 898–873 >98
Hexane 739–722 >95
Benzene 701–676 >97.1

Note—both spectra show bands near 2350 and 663 cm−1 due to CO2 and in the 3730–3570 cm−1 1640–1590 cm−1 regions due to H2O. These gases were not part of the original gas mixture and are likely contaminants associated with gases already trapped in the filter due to prior exposure to atmosphere, and the cryo-vacuum system used to condense the gases for FTIR measurement